Nexen Telemetry—energy and utilities management
Electricity, gas, water, heat, and compressed air on one hierarchy, with alerts before you breach the contracted limit and ISO 50001 data without a separate data-gathering project.
What Nexen Telemetry does
Measurement is the first step. We match it to the business goal, not the other way around.
electricity
natural gas
technical gases
water
heat
compressed air
Power Guard
Warning and critical thresholds per meter, with the alert routed to whoever can act on it.
Contracted-power optimization
Demand profile against the limit, from one hour to a year—your case for renegotiating.
Energy per unit produced
kWh per line, process, or part, measured against a target you set for it.
Virtual meters
A transformer or a whole hall reported on without a meter physically sitting on it.
Multiple sites
The same hierarchy on every site, so comparisons are like for like.
ESG and ISO 50001
Hourly to annual readings, exportable, with the alert record behind them.
Business benefits
- Lower bills—Fewer overrun and reactive-energy charges on the invoice.
- Better margins—Energy cost per part, not per accounting period.
- Earlier warnings—Overloads caught while there is still time to shift load.
- Audit-ready data—ESG and ISO 50001 without a separate data-gathering project.
Functionalities of Nexen Telemetry
- Thresholds per meter—warning and critical, set in the panel
- Alerts that reach assigned operators—routed by rule to named recipients
- The full history—threshold, value, size of breach, timestamp
- Active power against limits—gauge per point, updated live
- Full electrical picture—phase voltages, currents, power factor
- Energy import—today, week, month, year per meter
- Live status on the layout—reading and state per point
- Two clicks to a meter—plant, hall, switchboard, point
- Breaches highlighted in place—no cross-referencing a list
- Supply structure—main meter, transformers, switchboards, loads
- Group totals—power summed at every level
- One shared drawing—for energy, maintenance and automation
- Energy and production together—on one chart, one period
- A target you set—per line or per product, with the deviation
- Down to the machine—plant, line, or single asset
- Full parameter set—active and reactive power, currents, voltages, power factor, frequency
- Trends per parameter—from instantaneous peaks to annual profiles
- Ready for settlement—XLSX and CSV export
How to start
Start with one department to get a measurable result before any commitment.
1. Workshop and audit
Scope. Review of your switchboards and existing metering, power analyzers and gateways already installed, the utilities in scope, contracted power and current tariff terms, network and security constraints, and the costs you know are there but cannot quantify—overruns, reactive energy, energy per part.
Result. A metering point list ranked by financial impact, a target architecture, a defined pilot scope with success criteria, and an implementation plan with costing.
2. Metering pilot
Scope. A working installation on a limited area: one department, one line, or the plant’s main supply. Meters and analyzers installed or connected, a gateway, data acquisition, your plant structure and schematic set up in Nexen Telemetry, thresholds and alerts configured.
Result. Consumption data from your own switchboards, a measured baseline, verified data quality, and a business case built on your numbers.
3. Decision based on data
Scope. Pilot results against the agreed success criteria and the business case from the audit.
Result. A go / no-go decision with scope, budget, and timeline.
4. Deployment
Scope. Rollout to the agreed scope, delivered in stages without interrupting production.
Result. A production system with working integrations, trained users, and documentation.
5. Scaling
Scope. Further switchboards, utilities, and sites on the architecture already in place. Virtual meters, per-unit indicators, and reports added on top of the existing data layer.
Result. Consistent data and reporting across sites, without a second integration project.
Start with an audit or a pilot
Workshop and audit
Find out what your data is worth before you spend anything on collecting it.
Pilot or PoC
One line, your machines, your numbers. If they don’t work, you stop there.
Dive deep into the world of AI-powered software development

Industrial data acquisition for energy management—how we do it at Fabrity
Industrial data acquisition for energy management in brownfield factories—connect meters, close gaps, and turn readings into KPIs with Nexen Suite.

The LoRaWAN technology for industrial settings: Four practical use cases for 2026
Discover how LoRaWAN technology enables industrial IoT in harsh environments, with four practical use cases for 2026 covering maintenance, energy, processes, and safety.

From hidden losses to measurable savings: Reactive power optimization with Nexen EMS in production facilities
Discover how Nexen EMS helps production facilities cut energy costs by optimizing reactive power, eliminating penalties, and improving power quality.